Generic filters

Non-absorbable Titanium Membrane for predictable vertical and horizontal bone augmentation

OssBuilder

How do you benefit from the OssBuilder?

The Osstem OssBuilder is a high‑precision titanium membrane crafted for effective volume maintenance during bone regeneration. Its rigid, semi‑dome architecture accommodates alveolar defects without needing trimming or bending—streamlining GBR procedures while preventing soft‑tissue collapse.

Why It Matters for Clinicians

Bone volume restoration poses surgical challenges—especially when aesthetics and graft stability are critical. The Osstem OssBuilder addresses this by delivering a pre-shaped, rigid membrane that simplifies implantation, supports multiple defect morphologies, and enhances healing predictability. For clinicians, this translates into streamlined GBR workflows, reduced risk of exposure, and more reliable outcomes in both functional and aesthetic cases.

Key benefits

  • Pre‑Formed 3‑D Design
    Eliminates additional shaping steps—offering time‑saving convenience and wrinkle‑free placement.
  • Space Maintenance & Graft Stability
    Semi‑rigid dome shape prevents membrane collapse and preserves the graft’s volume during healing.
  • Designed for Complex Defects
    Available in OB2 (lateral defects) and OB3 (vertical/horizontal large defects) configurations—covering 1‑ to 3‑wall alveolar defects.
  • Optimized Pore Pattern for Vascularization
    Microporous structure promotes blood flow and effective fluid diffusion, supporting bone formation.
  • Integrated Anchoring & Caps for Surface Management
    Anchors, healing and cover caps support submerged or non‑submerged protocols while reducing risk of exposure.
Patient with enough gingiva
Patient without enough gingiva
3D Titanium Membrane for Predictable Bone Regeneration

OssBuilder adapts to each patient’s soft tissue condition with either a Cover or Healing Cap. Its pre-formed 3D design ensures stability, prevents membrane exposure, and supports faster, safer bone regeneration.

No Bending needed
Options for any indication
Design maximizing clinical convenience
  • 3D Pre-formed Design requires no trimming or bending
  • Line-up for various bone defect cases
Cover Cap
Healing Cap
Minimal exposure of membrane during Bone Healing
  • Suturing with Cover Cap H: 0.3mm minimizes the possibility of exposure
  • Healing Caps for non-submerged procedure for patients with insufficient soft tissues
No need for fixation screw
Cover Cap will fixate the titanium membrane
Minimal gingiva incision shortens recovery period
  • High-rigidity curved mesh maintains its shape without fixation screws
  • Secondary surgery can be performed with minimal incision
⚠️ This website is currently under development and is intended for internal review and feedback only. Content, including medical product information, is provisional and not intended for public distribution or use. No medical advice is provided.
Don't miss the Event of 2026

Osstem World Meeting 2026

Thailand, Bangkok

27. - 28. Apr. 2026

Save the Date

Días
Horas
Minutos
Segundos
This site is registered on wpml.org as a development site. Switch to a production site key to remove this banner.